Here’s what Autodesk says about SP1 for Civil 3D 2013:

In a continuing effort to provide high quality products, Autodesk has released AutoCAD Civil 3D 2013 Service Pack 1, which fixes or addresses a variety of issues discovered by customers and by Autodesk's internal testing team.

This Service Pack includes all previous hotfixes for AutoCAD Civil 3D 2013. It also includes the fixes included in AutoCAD 2013 Service Pack 1.1 and AutoCAD Map 3D 2013 Service Pack 1.

Note: This update applies to all language versions and to versions of AutoCAD Civil 3D 2013 with previous hotfixes applied. Before applying this update, make sure that any customizations made to the user profile (such as, customizations made to the support file search paths, print file customizations, printer support file paths, redirections, custom template settings, and so on) are exported to a secure location, then imported and reapplied after the update has been successfully installed. You cannot run an automatic uninstall to remove this update. To restore your version of AutoCAD Civil 3D 2013 to its pre-update state, uninstall AutoCAD Civil 3D 2013 and reinstall it.

The following issues have been resolved in AutoCAD Civil 3D 2013 Service Pack 1:

.NET API

  • The IsUsed property in StyleBase now reports whether a style is in use by an AutoCAD Civil 3D object.

Cogo

  • The COGO Editor now accepts Degrees/Minutes/Seconds in a spaced format.
  • The COGO Editor now retains the saved value in the description field.

Corridor Design

  • An issue with the Offset End Station value that prevented a drawing from opening has been resolved.
  • Switching between drawings while Station Tracker is enabled no longer causes the application to close unexpectedly.
  • An issue that caused errant feature lines to be generated between stations has been resolved.

Corridor Volumes

  • An issue where cut/fill volume shading was displaying incorrectly in some cross sections has been resolved.

Cross Section Views

  • The Update Section View Layout command no longer causes the application to close unexpectedly.
  • Opening a AutoCAD Civil 3D 2010 drawing containing the OverlayAndMill subassembly no longer results in a display issue with the section views.

Cross Sections

  • Selecting multiple existing polylines when creating sample lines no longer causes the application to close unexpectedly.

Data Exchange

  • An imported structure will now use the expected dimension rather than the dimension of the first structure of the imported group.

Feature Lines

  • Creating feature lines from objects when the objects are overlapping closed polylines no longer causes the application to close unexpectedly.

General/Other

  • An issue that caused an error when closing a drawing has been resolved.
  • An issue that caused an error when starting AutoCAD Civil 3D after migrating settings from a previous release has been resolved.
  • The stability of the Audit command has been improved.
  • Using the Move/Copy/Rotate Express Tool after grip editing an object no longer causes the application to close unexpectedly.
  • In drawings with a custom UCS, switching from the model tab to the layout tab will no longer reset model tab to isometric.
  • Using your mouse wheel to pan while in a command no longer causes an unexpected error.
  • Deleting the last remaining layout while set to model viewin that layout no longer causes the application to close unexpectedly.
  • File sync of custom Tool Palettes has been disabled.
  • Opening a drawing by double-clicking on the file no longer causes an unexpected error.
  • The performance of tooltips has been improved.
  • North rotation is now calculated as expected between Coordinate Settings and Geolocation.
  • An issue that caused an error when saving a drawing has been resolved.

Grading

  • An error while using the Grade to Surface command has been resolved.
  • Deleting a PI from a feature line no longer causes the application to close unexpectedly.

Hydraflow Storm Sewers

  • Storm Sewer calculations have been clarified to follow methodologies according to HEC-22.
  • Storm Sewers using HDS-5 inlet control option now report expected results.
  • The following issues related to inlet calculations and reporting have been resolved:
    • Inlet section view displays spread correctly in 2D when depression is ignored.
    • Slotted drains in sag condition now calculate expected depth and spread values while transitioning between weir and orifice flow.
    • Open Area Design calculations are now less than or equal to the product of grate length and width.
    • A column in theInteractive Designer is now labeled "Local Depression" to be consistent with the data-entry field.

Hydraflow Express

  • The following issues related to Inlet calculations and reporting have been resolved:
    • Inlet Section View display shows spread correctly in 2D when depression is ignored.
    • Slotted drains in sag condition now calculate expected depth and spread values while transitioning between weir and orifice flow.
    • Open Area Design calculations are now less than or equal to the product of grate length and width.
  • The following issues related to culvert calculations and reporting have been resolved:
    • Circular culverts now report consistent tailwater results as expected across a flow range.
    • Elliptical culvert calculations now report expected headwater values above the crown of the pipe.

Hydraflow Hydrographs

  • Hydrograph plots are now displayed correctly on computers running Windows XP 32-bit.

Inquiry

  • Switching between drawings while the Profile View Elevation and Grade Between Points inquiry command is active no longer causes the application to close unexpectedly.

Labels

  • An issue where referenced pipe spanning labels list the incorrect distance after reopening a drawing has been resolved.
  • An issue where referenced pipe network labels in section view disappear after reopening a drawing has been resolved.
  • Wipeout frames used in styles now display as expected.

LandXML

  • When importing LandXML data, alignments are now imported to the specified drawing layer.

Object Enabler

  • Importing a drawing using Navisworks Manage 2013 no longer results in the application becoming unresponsive or closing unexpectedly.

Parcels

  • Deleting a PI of a perimeter parcel no longer causes the application to close unexpectedly.

Pipe Networks

  • Solid hatching now displays as expected in profile views.
  • Issues recognizing the correct Manning roughness n-value for parts has been resolved.
  • Pipe length data is now available in structure tables displaying connected pipes.
  • Synchronizing a pipe network with a part swapped in the source drawing now updates the style as expected.

Points

  • Creating a point no longer fails if a survey point with the same number already exists in the drawing.
  • Assigning user-defined properties to a point group from the Summary tab no longer results in the application closing unexpectedly.
  • The next point number is now assigned correctly when creating points from objects.

Pressure Networks

  • Deleting pressure networks while the Pressure Network panorama is open no longer causes the program to close unexpectedly.
  • Minimum radius values for curved pipes are now updated when changing pipe sizes during layout.
  • Quantity takeoff reports now list lengths of pressure pipe when linear pay items are assigned.

Profiles

  • Grip editing a PVI marker with OSNAP enabled no longer causes the application to close unexpectedly.
  • Linetypes used for profiles that are referenced now appear as expected.

Project Management

  • Drawings with circular dependencies now generate a prompt when being checked in.
  • An error is no longer generated when checking in a drawing with a reference, when the reference drawing is checked out by another user.

Quantity Takeoff

  • The Pay Item and Pay Item Categorization files now default to the previously browsed path.

Reports

  • The PVI Station and Curve report is now generated correctly when the ambient setting for Grade/Slope format is set to Per Mille.

Shortcuts

  • An issue that allows the same profile object to be mapped to two different parent alignments has been resolved.
  • Performance when opening a drawing containing references has been improved.

Superelevation

  • The diagram in the Create Superelevation View dialog box is now displayed as expected when the alignment is referenced.

Surface

  • Watershed analysis performance on DEM surfaces has been improved.
  • The Drape Image command no longer results in a reversed image when hardware acceleration is enabled.
  • The stability of the Level of Detail command has been improved.
  • The stability of the Resolve Crossing Breaklines command has been improved.

Survey

  • The lower pane of Figure Properties dialog box now displays the Import Events as expected.
  • Modifying figure data in Figure Properties dialog box no longer causes the application to close unexpectedly.
  • Editing Chain Type Figure Properties no longer causes the layer to reset to 0.

Get SP1 here.

No comments:

Post a Comment

Subscribe to the comments feed

Some of the latest blog posts

Subscribe to RSS headline updates from:
Powered by FeedBurner

Contact Us | About JTB World | Subscribe to this blog
JTB World's website | Website General Terms of Use | Privacy Policy
^ Top of page

© 2004- JTB World. All rights reserved.